Remove the service panel on the goodman unit 5 16 screws where the power comes in.
Furnace blows fuse on circuit board.
It isn t the hsi inducer or blower motor as these are all high voltage parts not low voltage.
The good news and bad news about electric furnace troubleshooting.
Loose electrical cables there could be loose electrical cables inside the circuit box or somewhere in your ac which could be causing a short circuit.
The most probable of these are 1.
The contractor may be hanging up or shorting.
This was done after i couldn t get an appointment soon enough for a.
If the fuse blows when you have no low voltage wires hooked to the furnace then you have an internal problem like a bad limit gas valve connection or control board.
You need to find the root cause of the blown fuse on the furnace circuit board before you cause damage to the unit.
So i m working on a sure comfort nat gas furnace.
Within a 1 5 secs after i push door switch in the 3 amp fuse blows.
Furnace blowing cold air.
Check out this post.
Make sure there is not chafed wires.
Sometimes the blown fuse in the furnace comes from a malfunctioning transformer.
First the bad.
Blows the 3 amp fuse on the control board for my goodman ac unit.
If someone is poking around your furnace and is not too careful they could more wires so that they come into contact with the furnace s wire frame causing them to short and blow the fuse on the furnace board.
Diy and save 300 500.
After resetting the circuit breaker and replacing the fuse if the fuse keeps blowing there might be an electrical short in the electrical system that supplies the electricity to the furnace.
The furnace requires a lot of electricity to run and your home may not have the means to support it or there could be a short in the system.
In this case you should call an electrician.
Last guy replaced board already.
This is one of the most common reasons why the furnace fuse is blown.
Or just throw parts at it.
Here s how to diagnose a low voltage short.
Is your furnace running but blowing cold air.
If that all check out.
The coil in the contractor is 24v.
Amperage draw anything near the fuse rating would periodically blow a fuse.
There could be several reasons why air conditioner keeps blowing fuse in circuit board.
The stat wire feeds up through the bottom access hole.
If the fuse keeps popping in your air conditioner you have a 24 volt short.
I ve removed low voltage wires coming from thermostat and ac unit and i ve removed the 9 pin connector for the 24 volt circuit within the furnace.